PLC and device integration

Talk to the controllers you already have

Secure Sorter includes drivers for a wide range of programmable controllers and field devices, so a line is not forced through a single vendor's stack. Live writes are an administrator-controlled, audited capability, with safety and motor commands on a blocklist. Fieldbus protocols such as Modbus, EtherNet/IP and S7 are not natively encrypted — Electrol protects those links with network design and encrypted uplinks. Electrol commissions and tests the combination your site will actually run.

  • Logix, S7, Modbus, OPC UA, MQTT
  • MQTT over TLS, OPC UA SignAndEncrypt
  • Scanners, scales, printers
  • Audited live writes, with blocklists

Multi-vendor freedom, with controlled live writes

Use the controllers you already have. Live writes are administrator-controlled and audited, with safety and motor commands on a blocklist.

Logix EtherNet/IP

Browse, typed read, confirmed writes

Allen-Bradley Logix over EtherNet/IP: symbolic browse, typed reads and confirmed writes, with a live watch path used in commissioning. Legacy PCCC covers MicroLogix, SLC 500 and PLC-5 class addressing.

Siemens and the open set

S7, Modbus, OPC UA, MQTT

Siemens S7 communications, Modbus TCP, MQTT over TLS — including Sparkplug-style edge publishing where the project uses it — and an OPC UA client that prefers Aes256_Sha256_RsaPss SignAndEncrypt.

Other controllers

FINS, MELSEC, ADS, and more

Omron FINS, Mitsubishi MC protocol and Beckhoff ADS are in the platform, alongside DNP3 and BACnet/IP for utility and building work when a site needs them.

Scan, weigh, print

The devices around the divert

Industrial scanner connections — including Cognex, Datalogic, SICK and Keyence, plus a generic TCP scanner — scales including Mettler Toledo SICS, and label printers in the ZPL and SBPL families.

Live writes, under an administrator

Audited, with blocklists that stay on

Live writes to a controller are an administrator-controlled, audited capability. Safety, motor and PLC-mode commands stay on a blocklist that cannot be turned off. An optional tag allow-list can further limit what may be written. Handshake tags are reserved for the gateway.

Commissioned per site

Present in the platform, proven on the project

Which drivers are used on a given line, and how they are tested, is part of Electrol's commission for that site. The list describes software that exists in the platform. It is not a vendor certification. Modbus TCP, EtherNet/IP and S7 are not natively encrypted; Electrol mitigates with CIP Security where supported, a segmented OT network, a VPN or IPsec tunnel, or an edge gateway next to the PLC with an encrypted uplink.

Guarded commissioning writes

A one-shot Logix write during setup requires a preview, a short-lived confirm token, and an equipment acknowledgement. Those writes are for commissioning, not everyday plant control. Importing an L5X definition, browsing a controller or reading live values does not download a program to a PLC. Program download, firmware and run/stop remain in the vendor engineering tool.

Tell Electrol which controllers are on the floor

A short note on the family you have — Logix, S7, or something else — is enough to start. [email protected]